Refine your search:     
Report No.
 - 
Search Results: Records 1-5 displayed on this page of 5
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

None

; ;

PNC TN2410 93-017, 107 Pages, 1993/05

PNC-TN2410-93-017.pdf:12.88MB

None

JAEA Reports

None

; Sumino, Kozo; Yasu, Tetsunori; ; ; ; Terunuma, Seiichi

PNC TN9410 91-376, 79 Pages, 1991/11

PNC-TN9410-91-376.pdf:1.9MB

None

Journal Articles

Study on regeneration of activated carbon by means of electron radiation (in Chinese)

G.Zhu*; Arai, Hidehiko; Hosono, Masakazu

J. Radiat. Res. Radiat. Process., 9(1), p.54 - 58, 1991/02

no abstracts in English

JAEA Reports

Results of "Monju" Super-heater warmming simulation test survey of temperature fluctuation at tube-sheet and confirmation of pre-heating effect

Ohtaki, Akira

PNC TN9410 90-062, 145 Pages, 1990/04

PNC-TN9410-90-062.pdf:3.21MB

It is important to control an operation to avoid water flow in which cause of SCC for a superheater which is made by astinetic stainless steel. During the superheater war㎜ing operation at the 50MW Steam Generator Test Facility, temperature fluctuation at the inlet tube sheet are easily occurred, and existence of saturated water with in warmming steam is regarded as the cause of it. A test simulating operating conditions of "Monju" superheater warmming was carried out to comfirm start up condition of "Monju". Test results show that a part of war㎜ing steam was cooled down to saturated temperature in main steam pipe which temperature is still lower than the saturated temperature, then the saturated water flows in the tube sheet which temperature is as high as sodium inlet temperature, and cause the temperature fluctuation. In order to confirm the effect of pre-heating the main pipe using trace line, a trace line was adapted at the main steam pipe, and the same superheater warmming simulation test was performed. Test results show that trace line was effective to pre-heat the main steam pipe exceeding temperature, and the temperature fluetuation was considerably decreased.

Oral presentation

Capability study on robustness improvement using the maintenance cooling system in MONJU, 2; Seismic response analysis of preheating system

Matsui, Kazuaki; Imo, Kazumichi*; Mitsumoto, Rika; Ando, Masanori; Futagami, Satoshi

no journal, , 

no abstracts in English

5 (Records 1-5 displayed on this page)